You need only one blood withdrawal to perform the two tests d-ROMs fast and PAT.
Reading times are the shortes: two and half minutes for d-ROMs fast test and 1 minute for PAT test.
PAT is the most recent evolution in the test for the evaluation of antioxidants:
it is the only test that eliminates the interferences of phosphates and therefore it is both the most specific and the fastest.
The SAT test allows the evaluation of the antioxidant activity of saliva helping the prevention of problems and diseases in the oral cavity.
Thanks to these real-time tests, it is possible to establish an accurate and reliable diagnosis of oxidative stress. By these assessment only, you can optimize specificantioxidant therapies and monitor their effectiveness.
The software can be updated and new tests can be added by means of a USB connection with a PC.
More information can be obtained by contacting H&D by email at info@hedsrl.it.
Technical characteristic FRAS 5
General Characteristics | |
Dimension Weight Power Supply Consumption |
40 x 26,5 x 13 cm 2,6 Kg 100m ÷ 240 VAC, 50 ÷ 60 Hz 60W |
Fotometric system | |
Light source Spectral range Measuring principle Temperature |
High efficency led 505 nm interferential filter Lambert Beer’s law 37°C real time displayed |
Centrifuge | |
Speed Positions Temperature |
6000 r.p.m. ±5% 2 – 4 cuvettes 37°C real time dispayed |
Software | |
Program Interface |
Resident on Flash memory R2 232 a 9 poli for PC connection |
Display | |
TouchScreen backlit graphic |
|
Printer | |
Type Result |
Grafic, thermic, with 384 dots per line Automatic printout |
Autodiagnosis | |
Automatic error display |
|
Operating condition | |
Temperature Relative humidity |
15 – 35°C Max 90% |
Regulation | |
Directive 73/23 CEE e 93/68 CEE (electrical safety) Directive 98/79 EC (IVD) Directive 89/336/CEE (electromagnetic compatibility) |